A furnace that clicks, hums, then falls silent without heat is failing somewhere in its ignition sequence. On newer systems the usual culprits are a cracked or worn hot surface ignitor, a flame sensor coated in oxide so it cannot prove flame, or a pressure switch that will not close because the flue or condensate line is blocked. On older standing-pilot units, a pilot that lights but will not stay lit usually points to a failing thermocouple or a draft reaching the pilot assembly.

These faults follow a diagnosable order and a professional will work through it rather than replacing parts on guesswork. Repeated ignition lockouts should not be reset over and over, since each attempt puts unburned gas into the chamber. Pro HVAC connects homeowners in Shaker Heights, OH with HVAC professionals. Call (321) 463-9811.

How it works

Four simple steps to Furnace Repair in Shaker Heights, OH

01

Tell us the symptom

Tell us what your system is doing in Shaker Heights, OH.

02

Matched to the fault

We match the symptom to a professional who handles that fault.

03

They contact you

They contact you directly to arrange the visit.

04

If it is not right

If they cannot help, tell us and we find another.

Coverage

Furnace Repair Services Across Shaker Heights, OH

Covering Shaker Heights, OH and nearby ZIPs across Ohio.

Neighborhoods we cover for Furnace Repair

  • Lomond
  • Sussex
  • Boulevard
Furnace Ignition And Pilot Light Repair in Shaker Heights, OH

Furnace Ignition And Pilot Light Repair FAQs

Frequently asked questions about Furnace Ignition and Pilot Light Repair

Questions we hear most often about Furnace Ignition and Pilot Light Repair in Shaker Heights, OH.

Talk to a real person
Why is my furnace blowing cold air instead of heat?
A dirty air filter restricts airflow and often causes a furnace to blow cold air. Turn the system off, replace the filter with the correct size, and wait 30 minutes before restarting. Check that the thermostat is set to heat mode and the temperature is higher than room temperature. In Shaker Heights, OH winters, a clogged filter can lead to frozen coils if ignored. If the problem continues after the filter change, the issue may involve the blower motor or limit switch.
What causes my furnace to short cycle on and off?
Short cycling is most often caused by a dirty filter or blocked return vents that make the unit overheat and shut down. Replace the filter, clear vents, and make sure supply registers are open. A thermostat placed in direct sunlight or near a lamp can also cause rapid cycling. In Shaker Heights, OH winters this wastes fuel and stresses the heat exchanger.
Why does the pilot light on my furnace keep going out?
A weak thermocouple or drafts around the burner compartment usually cause the pilot to extinguish. First, ensure the furnace door is fully closed and the area around the unit is free of strong air currents. If the pilot still will not stay lit after relighting per the label instructions, turn the gas valve off and do not attempt further adjustments.
Do I need an AC recharge, or do I have a refrigerant leak?
A sealed air conditioning system does not use refrigerant up, so if the charge is low there is a leak somewhere. Cooling that weakens season after season, ice on the line set, or a hissing sound near the indoor unit all point to a leak rather than normal top-up. Adding refrigerant without locating the leak means paying again next season, and running low charge makes the compressor run hot. Ask for the leak to be found and quoted before agreeing to a recharge in Shaker Heights, OH.
Can a dirty air filter really break my heating or cooling system?
Yes, and it is the most common cause of faults that look like equipment failure. A restricted filter makes a furnace overheat and shut down on its limit switch, freezes an air conditioning evaporator coil solid, and makes the blower motor draw high current until it fails early. Two things matter more than brand: the filter must fit its slot tightly, because a loose filter lets air bypass it completely, and a very high MERV rating in a system not designed for it restricts airflow enough to cause the same overheating it was meant to prevent. A filter that darkens within weeks in Shaker Heights, OH usually means duct leakage is pulling in unfiltered air.